Fully Automatic Microhardness Testing solution
Clemex CMT (Automatic)
If your laboratory needs a robust solution for high throughput environments,
then the Clemex CMT (automatic) solution is the path to take. Fully equipped
with a state-of-the-art microhardness testing machine, ASTM E-384 and DIN/ISO
6507 compliant Clemex CMT Software, a high resolution camera, and a high
performance computer, you can rest assured that you'll have all you need to
extract fast, accurate and repeatable test results. Clemex CMT (automatic)
performs tests in just 4 easy steps!

| Options |
Dual indenter
|
 |
If you need to measure both
Knoop and Vickers then the
Clemex Microhardness Tester
Dual Indenter is the instrument
you need. Both indenters
are installed permanently,
so there is no need to change
the synthetic diamond.
Save time!
With the Clemex Microhardness Tester Dual Indenter you can now measure both Vickers and Knoop on the same machine! (All results can be converted to Rockwell with the software) No need to run your tests on two separate machines or to do a first test, change the indenter and do the second test.
Save money!
Use only one instrument instead of two. With the Dual Indenter, both
Vickers and Knoop measurements can be performed on the same machine!
|
| |
|
Sample Holder
|
 |
Clemex Sample Holder has
a unique design, as you can
see a test block is always
next to your sample allowing
the user to calibrate the microhardness
tester at any time without
having to remove the sample.
The sample holder can take
different sample sizes and
sample is easily removed with
a drawer system. |
| Software - 4 easy steps to run your test |
| STEP 1 - Position Sample |
 |
Position sample material on the self-leveling or universal vise. No need to worry about sample orientation. The T-BAR rotation tool allows you to orient the stage pattern at any angle. |
| STEP 2 - Set Stage Pattern |
 |
Load a predefined stage pattern or define a new one with a few simple mouse clicks. Position stage to the sample starting point and set the origin. You can set up to 36 samples or traverses of any number of indents. |
| STEP 3 - Run Sequence |
 |
Launch the test by clicking on the run icon. The system intelligently follows the predefined pattern and focuses automatically when needed. Indents are measured instantaneously and data generated dynamically. |
| STEP 4 - Report |
 |
Review statistical results in graphical and/or tabular format. Export results to the spreadsheet application of your choice or simply print standard or customized reports. |
|
|
|
|
| Video |
Case Depth one traverse
Case Depth multiple traverses
Weld traverse
Position Sample
Stage Pattern
Run Sequence
|
| Sample Holders |
Our sample holders integrate a test block for automatic or manual calibration!
|
|
|